• Secondary Coil of CT for Circuit Breakers
Secondary Coil of CT for Circuit Breakers
+

Secondary Coil of CT for Circuit Breakers

Main products of the company: current transformer cores, transformer laminated cores, magnetic shielding, current transformer coils, etc. Certified by ISO9001 quality management system, ISO14001 environmental management system, and OHSAS18001 occupational health management system.

Materials used CT Technical Specifications

Reference Standard:GB1208-2006 Current Transformers

Voltage Class:35KV-800KV

Primary Current:50A~5000A

Secondary Current:1Aor5A

Dimensions: Customized per customer requirements

Product Features

Annular Core Winding:High-quality raw materials with optimized calculations.

Performance: Provides high accuracy and load capacity under specified constraints, meeting all customer-defined performance indicators.

Routine Inspections

1. Visual Inspection 

2. Terminal Marking Verification 

3. Insulation Resistance Measurement 

4.Power Frequency Withstand Voitage Test(secondary winding to ground)

5.Polarity Check 

6.Inter-tum Overvoltage Test 

7.Accuracy Class&Error Determination 

8. Composite Error Measurement 

9.Transient Error Measurement(for transient protection CTs only)

Notes:

CT=Current Transformer (retain standard abbreviation).

GB1208-2006:China national standard for current transformers.

Transient Current Transformer:Transient protection CTs(e.g.,TPY class for high-speed protection systems).

All test names follow IEC 60044-1 terminology where applicable.


Contact: General Manager Yao +86-13584935499

  • Product Description
  • Materials used CT Technical Specifications

    Reference Standard:GB1208-2006 Current Transformers

    Voltage Class:35KV-800KV

    Primary Current:50A~5000A

    Secondary Current:1Aor5A

    Dimensions: Customized per customer requirements

    Product Features

    Annular Core Winding:High-quality raw materials with optimized calculations.

    Performance: Provides high accuracy and load capacity under specified constraints, meeting all customer-defined performance indicators.

    Routine Inspections

    1. Visual Inspection 

    2. Terminal Marking Verification 

    3. Insulation Resistance Measurement 

    4.Power Frequency Withstand Voitage Test(secondary winding to ground)

    5.Polarity Check 

    6.Inter-tum Overvoltage Test 

    7.Accuracy Class&Error Determination 

    8. Composite Error Measurement 

    9.Transient Error Measurement(for transient protection CTs only)

    Notes:

    CT=Current Transformer (retain standard abbreviation).

    GB1208-2006:China national standard for current transformers.

    Transient Current Transformer:Transient protection CTs(e.g.,TPY class for high-speed protection systems).

    All test names follow IEC 60044-1 terminology where applicable.

Main products of the company: current transformer cores, transformer laminated cores, magnetic shielding, current transformer coils, etc. Certified by ISO9001 quality management system, ISO14001 environmental management system, and OHSAS18001 occupational health management system.

Secondary Coil of CT for Circuit Breakers

Main products of the company: current transformer cores, transformer laminated cores, magnetic shielding, current transformer coils, etc. Certified by ISO9001 quality management system, ISO14001 environmental management system, and OHSAS18001 occupational health management system.

Materials used CT Technical Specifications

Reference Standard:GB1208-2006 Current Transformers

Voltage Class:35KV-800KV

Primary Current:50A~5000A

Secondary Current:1Aor5A

Dimensions: Customized per customer requirements

Product Features

Annular Core Winding:High-quality raw materials with optimized calculations.

Performance: Provides high accuracy and load capacity under specified constraints, meeting all customer-defined performance indicators.

Routine Inspections

1. Visual Inspection 

2. Terminal Marking Verification 

3. Insulation Resistance Measurement 

4.Power Frequency Withstand Voitage Test(secondary winding to ground)

5.Polarity Check 

6.Inter-tum Overvoltage Test 

7.Accuracy Class&Error Determination 

8. Composite Error Measurement 

9.Transient Error Measurement(for transient protection CTs only)

Notes:

CT=Current Transformer (retain standard abbreviation).

GB1208-2006:China national standard for current transformers.

Transient Current Transformer:Transient protection CTs(e.g.,TPY class for high-speed protection systems).

All test names follow IEC 60044-1 terminology where applicable.

Related Products

Product Inquiry

*Note: Please be sure to fill in the information accurately and keep communication open, we will contact you as soon as possible!

Powered by 300.cn

Business License